<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-04 04-49-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 67 kHz 12556 11,8987
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 4,91 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 67 kHz MIN: 11 kHz % above 76 kHz: 11,8987 Acquired: 2025/05/04 4.48.49 Total samples: 12556 Equivalent time: 0:10:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400 500
FM Scope MAX: 5,7 dBr MIN: 3,0 dBr AVE: 4,91 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/05/04 4.48.49) 04.34 04.36 04.38 04.40 04.42 04.44 04.46 04.48 0 2 4 6 Pm [dBr]